Encapsulated bleb is a localized, dome-shaped filtering bleb enclosed by a thick fibrous wall of Tenon tissue. Clinicians also call it a Tenon cyst or encysted bleb. It usually appears weeks after trabeculectomy and causes a rise in intraocular pressure (IOP).
What an Encapsulated Bleb Is
Aqueous still leaves the eye through the sclerostomy and scleral flap. However, a fibrous capsule forms beneath the conjunctiva and confines the fluid to a small space. As a result, the bleb becomes high and tense, while its absorbing surface stays small.
Timing and IOP Pattern
The typical history is a good early result followed by a pressure rise, and encapsulation usually develops between the second and eighth postoperative week (see trabeculectomy). Then IOP climbs as the capsule matures, while the anterior chamber stays deep and formed. Late encapsulation, months after surgery, is less typical.
All-fit Slit-Lamp Adapter
Record and share exactly what you see at the slit lamp. One adapter fits any slit lamp or surgical microscope — and any smartphone.
From Choroida — the team behind this siteSlit Lamp Signs of an Encapsulated Bleb
The examiner sees a smooth, elevated, dome-shaped bleb with a firm, tense wall. Overlying vessels are engorged, and the wall lacks the microcysts of a functioning diffuse bleb, while the surrounding conjunctiva often looks flat and vascular. The Seidel test is negative because the wall is thick and intact.
Encapsulated Bleb After Tube Surgery
A similar process occurs around the plate of a drainage device (see tube shunts). After an Ahmed valve, a hypertensive phase often begins within the first few months, and then a tense elevation may appear over the plate, usually superotemporally, while management follows similar principles.
Risk Factors
Most data come from retrospective series, so treat these associations with caution.
- Previous conjunctival or filtering surgery
- Long-term topical glaucoma medication before surgery
- Previous argon laser trabeculoplasty
- Young age
- Surgery without an antimetabolite
Differential Diagnosis
Before labeling the bleb encapsulated, exclude other causes of high IOP after filtration surgery.
- Aqueous misdirection, where the anterior chamber is shallow
- Suprachoroidal hemorrhage, with pain and a shallow chamber
- Blebitis, where the bleb looks milky and injected (see bleb-associated endophthalmitis)
Imaging an Encapsulated Bleb
Anterior segment OCT shows a thick, hyperreflective wall around a large, hyporeflective fluid cavity, and it also shows few intrableb microcysts, unlike a functioning bleb. Ultrasound biomicroscopy can demonstrate the patent sclerostomy beneath the cyst.
Why Wait Before Intervening
Many encapsulated blebs soften and flatten over the following months, and early series reported that most eyes reached acceptable IOP with medical treatment alone. Therefore, observation is reasonable when the optic nerve can tolerate it. However, advanced glaucoma with threatened fixation lowers the threshold for early action.

Medical Therapy for Encapsulated Bleb
Aqueous suppressants lower IOP while the capsule remodels, and beta-blockers, carbonic anhydrase inhibitors and alpha agonists are common choices. Some surgeons also continue topical steroids to limit further fibrosis, and patients should know that these drops may be temporary.
Digital Massage
Massage pushes aqueous into the cyst and may stretch the capsule. The patient presses through the lower lid on the inferior globe, following surgeon instruction, but vigorous massage can cause a leak, hyphema or overfiltration.
Needling an Encapsulated Bleb
Needling opens the fibrous wall with a fine needle, usually at the slit lamp. The needle enters the conjunctiva at a distance, then cuts the capsule in several directions, and a successful pass shows the bleb spreading and IOP falling at once. For technique details, see our guide to bleb needling.
Antimetabolites During Needling
Surgeons often inject 5-fluorouracil or mitomycin C next to the bleb. These agents reduce recurrent fibrosis, although evidence comes mostly from case series. They also raise the risk of epithelial toxicity, leak and later infection. Therefore, check for a leak after every injection.
Surgical Revision
When needling fails repeatedly, the surgeon may excise the capsule. This involves opening the conjunctiva, removing the thick Tenon wall and often applying an antimetabolite. Alternatively, a new filtering procedure at another site or a tube shunt may suit the eye better.
Counseling the Patient
Patients often feel the operation has failed when drops return. Explain that the drainage channel remains open and the problem lies in the scar wall, and ask them to report pain, redness, discharge or blurred vision immediately, because these may signal infection.
Follow-Up of an Encapsulated Bleb
Measure IOP and grade bleb height, vascularity and extent at each visit. After needling, review the eye within days, then space visits as IOP settles, and finally watch for thin, avascular areas after antimetabolite use.
Pitfalls to Avoid
- Do not needle an eye with a shallow chamber before excluding aqueous misdirection
- Avoid early revision when medical therapy controls IOP
- Never skip the Seidel test after needling


Document what you see
Two smartphone imaging tools built for everyday clinic use — one for the slit lamp, one for the fundus.
From Choroida — the team behind this siteReferences
- Van Buskirk EM. Cysts of Tenon’s capsule following filtration surgery. Am J Ophthalmol. 1982;94:522-527.
- Sherwood MB, Spaeth GL, Simmons ST, et al. Cysts of Tenon’s capsule following filtration surgery: medical management. Arch Ophthalmol. 1987;105:1517-1521.
- Richter CU, Shingleton BJ, Bellows AR, et al. The development of encapsulated filtering blebs. Ophthalmology. 1988;95:1163-1168.
- Feldman RM, Gross RL, Spaeth GL, et al. Risk factors for the development of Tenon’s capsule cysts after trabeculectomy. Ophthalmology. 1989;96:336-341.