Tube exposure is erosion of the conjunctiva and patch graft over a glaucoma drainage device. It leaves the silicone tube or plate open to the tear film. Because the bare implant gives bacteria a direct path into the eye, every case needs prompt recognition and a clear repair plan.
What Tube Exposure Means
A glaucoma drainage device routes aqueous through a silicone tube to an equatorial plate. A patch graft usually covers the tube near the limbus (see glaucoma drainage devices). When the overlying tissue melts or retracts, the tube surface becomes visible, so the barrier between the ocular surface and the anterior chamber is lost.
Why Tubes Erode
Most erosions develop where the tube crosses the limbus, because blinking rubs the eyelid against the raised tube and its graft thousands of times a day. In addition, tissue over the tube can thin from chronic inflammation, poor conjunctival vascularity or graft resorption. Tight sutures and a stiff tube angle also add focal pressure.
All-fit Slit-Lamp Adapter
Record and share exactly what you see at the slit lamp. One adapter fits any slit lamp or surgical microscope — and any smartphone.
From Choroida — the team behind this siteRisk Factors for Tube Exposure
- Inferior or inferonasal quadrant placement
- Prior conjunctival surgery, for example a failed trabeculectomy
- Thin, scarred or cicatrized conjunctiva
- Chronic ocular surface disease and long-term preserved drops
- Uveitis and other chronic inflammatory eye disease
- A tube placed too anteriorly or raised above the scleral surface
Slit Lamp Signs of Tube Exposure
Under diffuse light, an exposed tube appears as a smooth white or gray cylinder on the surface. A rim of injected, rolled conjunctiva often surrounds the defect. Fluorescein then stains the bare area, and a positive Seidel test means aqueous is leaking along the tube track (see slit lamp illumination techniques).
Thinned Graft or True Exposure?
A melting patch graft often becomes translucent, so the tube shows through as a gray shadow. The conjunctiva above it stays intact and does not stain. These eyes need closer review, and many surgeons repair early when thinning progresses. True exposure, however, involves an epithelial defect that stains and carries a much higher infection risk.
Plate Exposure and Extrusion
Exposure of the plate is less common. It usually follows wound breakdown, migration or extrusion of the implant toward the limbus. The plate edge or fixation sutures may appear in the fornix with a large conjunctival defect, therefore simple coverage seldom succeeds unless the surgeon also addresses plate position.
Endophthalmitis Risk in Tube Exposure
Late endophthalmitis after drainage device surgery has been strongly associated with conjunctival erosion over the tube, particularly in children. The tube connects the tear film with the anterior chamber, so organisms can enter directly. Treat any exposed device as a portal of infection until it is covered.
When pain, vitritis or hypopyon appear, manage the eye as acute endophthalmitis with a vitreous tap and intravitreal antibiotics. Many authors then favor device removal, since infected silicone is hard to sterilize (see bleb-associated endophthalmitis).

Urgent Triage of Tube Exposure
Any true exposure deserves surgical repair within days, while signs of infection need same-day assessment. Meanwhile, start a broad-spectrum topical antibiotic and ask about pain and discharge. Then document intraocular pressure, chamber depth and the size of the defect with slit lamp photography.
Patch Graft Repair of Tube Exposure
Simple conjunctival closure over a bare tube tends to fail, because the conjunctiva retracts and erodes again over the same ridge. Therefore, most surgeons debride the defect edges and remove necrotic graft. They then place a fresh patch of donor sclera, cornea or processed pericardium, secured with sutures or fibrin glue.
Conjunctival Coverage and Adjuncts
The graft must sit under healthy, well vascularized tissue. For this reason, surgeons mobilize an adjacent conjunctival flap or harvest a free conjunctival autograft. Amniotic membrane can also support the surface in scarred eyes, although it works best as an adjunct and seldom serves as the sole cover.
When to Reposition or Remove the Device
Recurrent exposure at one site suggests a mechanical cause. Therefore, surgeons may shorten the tube, redirect it through a longer scleral tunnel or move the entry to the ciliary sulcus. Removal becomes the safer choice with active endophthalmitis, plate extrusion or repeated failed repairs, and the patient then needs another pressure-lowering plan.
Counseling After Tube Exposure Repair
Explain that exposure alone rarely blurs vision, while infection can threaten sight. Any red, painful or sticky eye therefore needs review the same day. After repair, the patient should also use the prescribed drops, avoid rubbing and attend early visits, because recurrent thinning can appear within months.
Pitfalls to Avoid
- Do not mistake a thinned but epithelialized graft for exposure, or the reverse
- Never close a bare tube with conjunctiva alone and expect lasting cover
- Do not overlook a small defect hidden under the upper lid
- Never delay repair in a child with an exposed tube


Document what you see
Two smartphone imaging tools built for everyday clinic use — one for the slit lamp, one for the fundus.
From Choroida — the team behind this siteReferences
- Gedde SJ, Scott IU, Tabandeh H, et al. Late endophthalmitis associated with glaucoma drainage implants. Ophthalmology. 2001;108:1323-1327.
- Gedde SJ, Herndon LW, Brandt JD, et al. Postoperative complications in the Tube Versus Trabeculectomy (TVT) study during five years of follow-up. Am J Ophthalmol. 2012;153:804-814.
- Levinson JD, Giangiacomo AL, Beck AD, et al. Glaucoma drainage devices: risk of exposure and infection. Am J Ophthalmol. 2015;160:516-521.
- Smith MF, Doyle JW, Tierney JW Jr. A comparison of glaucoma drainage implant tube coverage. J Glaucoma. 2002;11:143-147.
- American Academy of Ophthalmology. Basic and Clinical Science Course, Section 10: Glaucoma. San Francisco: AAO; 2024.