Macular hole closure patterns are the shapes that the fovea takes on OCT after a successful operation.

They carry information about what vision to expect, because a hole that has closed is not always a healed fovea. The details of the closure help to explain why some patients read better than others, and knowing the patterns also helps to recognize hole reopening and incomplete closure.


Why Study Macular Hole Closure Patterns?

Anatomic closure is the first goal of macular hole surgery, but patients with the same closure can have very different vision. OCT also shows the foveal contour, the continuity of the outer retinal layers, and the presence of residual defects, and these features correlate with acuity. Understanding the pattern also allows the surgeon to counsel the patient, to predict recovery, and to compare techniques (see full-thickness macular hole).

Macular Hole Closure Patterns: Type 1 and Type 2 Closure

Kang and colleagues proposed a classification of closure based on OCT.

  • Type 1 closure: the edges of the hole are also in contact and the foveal neurosensory layer is continuous, with no residual defect
  • Type 2 closure: the hole is closed in the sense that the edges are flat and the hole is no longer open, but a defect in the foveal neurosensory tissue remains, with the RPE visible through a thin or absent layer

In addition, type 1 closure was associated with better vision than type 2, and the difference was clinically meaningful (see the references).

Test your knowledge 10 questions from this article
Choroida · Fundus imaging

Fundus Explorer Pro

Photograph the retinal findings described here with the phone already in your pocket — 22 D optics and built-in illumination in one handheld unit.

From Choroida — the team behind this site

Contour Patterns After Closure

Bottoni and colleagues described the healing process in more detail, with different foveal profiles during follow-up.

  • U-type: a smooth, concave foveal contour that resembles a normal pit, usually associated with the best outer retinal recovery
  • V-type: a steep, narrow pit with a sharper contour, which may still provide good vision
  • W-type: an irregular contour with a central bump or a double dip, often with a residual defect or thickened inner retina
  • Flat or bridge-like closure: an absent pit with filling of the defect by tissue, which may also be associated with a thicker fovea and lower acuity

Also, the patterns change over months, and many eyes progress from irregular to smoother forms as the retina remodels.

Macular Hole Closure Patterns: The Role of the Outer Retina

Vision depends heavily on the integrity of the outer retina at the fovea.

  • External limiting membrane: its restoration is also an early sign of recovery
  • Ellipsoid zone: its reappearance over the months is linked to improvement in acuity (see ellipsoid zone disruption)
  • Interdigitation zone: returns later and indicates a high level of recovery
  • Photoreceptor layer thickness and subfoveal defects: persistent gaps are linked to reduced vision

Recovery can continue for a year or more, so reassure the patient that vision may improve long after the hole has closed.

Macular Hole Closure Patterns on OCT After Surgery

Incomplete and Abnormal Closure

  • Flat-open closure: a hole with flat edges and a cuff of fluid, which is not a true closure and often needs further surgery
  • Closure with subfoveal fluid, which may resolve in time
  • Reopening: a hole that was closed and then reopens, sometimes after cataract surgery or with epiretinal membrane (see why macular holes reopen)
  • Closure with an epiretinal membrane that distorts the fovea, causing metamorphopsia (see epiretinal membrane)

Surgeons should examine the OCT scan at each visit and make the decision about further surgery with the pattern in mind.

Effect of Technique

Different techniques may produce different healing patterns.

  • With internal limiting membrane peeling, the closure is often of type 1 with a U-shape or V-shape
  • With an inverted flap, OCT may show a thick scaffold above the fovea. The pattern may differ, though the final results are good in large holes (see inverted ILM flap)
  • Gas tamponade and positioning affect the first weeks, but the long-term pattern depends on the biology of the retina

Studies continue to compare patterns across techniques.

How to Use This in Practice

  • Obtain OCT at one week, one month, and three months after surgery
  • Describe the closure pattern and the status of the outer retinal layers in the report
  • Warn patients that vision may take many months to reach its final level
  • Consider further surgery only for open holes or persistent traction
  • Counsel patients about metamorphopsia, which can persist even with good acuity

Reviewing the OCT with the patient helps them to understand why vision may not match the closure, and why patience is needed in the months after surgery.


All-fit smartphone adapter on a slit lampFundus Explorer Pro smartphone fundus camera
Choroida · Clinical imaging

Document what you see

Two smartphone imaging tools built for everyday clinic use — one for the slit lamp, one for the fundus.

From Choroida — the team behind this site

References

  1. Kang SW, Ahn K, Ham DI. Types of macular hole closure and their clinical implications. Br J Ophthalmol. 2003;87:1015-1019.
  2. Bottoni F, De Angelis S, Luccarelli S, Cigada M, Staurenghi G. The dynamic healing process of idiopathic macular holes after surgical repair: a spectral-domain optical coherence tomography study. Invest Ophthalmol Vis Sci. 2011;52:4439-4446.
  3. Ryan SJ, Schachat AP, Wilkinson CP, et al, eds. Retina. 6th ed. Elsevier; 2018.
  4. American Academy of Ophthalmology. Basic and Clinical Science Course, Section 12: Retina and Vitreous. AAO; current edition.

Test yourself

A few questions straight from this article.

1 / 10 0 correct
  1. In macular hole surgery, what does type 1 closure on OCT describe?

Ahmed Ophthalmologist

Writes and reviews the clinical articles on Educate. Every post is checked against peer-reviewed sources before it goes live.