Van Herick test estimates peripheral anterior chamber depth at the slit lamp in under a minute.

It compares the limbal chamber gap with the thickness of the adjacent cornea, and as a result it flags eyes that need gonioscopy. However, it screens the angle and cannot replace a direct view of it.


What the Van Herick Test Measures

Van Herick, Shaffer and Schwartz described the method in 1969, and the examiner judges the dark gap between the corneal endothelium and the peripheral iris. Because this gap lies near the angle recess, it indirectly estimates angle width, so the cornea serves as a built-in ruler.

Slit-Lamp Setup

First, use moderate magnification and a thin, bright slit, and next set the illumination arm 60 degrees from the microscope axis. Then aim the beam perpendicular to the cornea at the temporal limbus. Finally, dim the room lights so the dark gap stands out (see slit-lamp illumination techniques).

Test your knowledge 10 questions from this article
Choroida · Slit-lamp imaging

All-fit Slit-Lamp Adapter

Record and share exactly what you see at the slit lamp. One adapter fits any slit lamp or surgical microscope — and any smartphone.

From Choroida — the team behind this site

Beam Position in the Van Herick Test

The slit must fall right at the limbus, just inside clear cornea, and if it lands too far centrally, the chamber looks deeper than it is near the angle. Meanwhile, the patient looks straight ahead while you view the section from the front.

Grading the Van Herick Test

Compare the dark gap with the corneal section width in the same view.

  • Equal to or wider than corneal thickness: grade 4, closure very unlikely
  • One quarter to one half: grade 3, closure unlikely
  • About one quarter: grade 2, closure possible
  • Less than one quarter: grade 1, closure likely
  • No visible gap: grade 0 in many modified charts, angle probably closed

The Modified Foster Scale

Foster and colleagues refined the scheme in 2000 for screening in Asian populations, and they recorded limbal chamber depth as a percentage of corneal thickness, using finer steps. Therefore, the scale helps when you track small changes over time.

How the Van Herick Test Correlates With Gonioscopy

Grades 3 and 4 usually match an open angle on gonioscopy, but agreement weakens in the middle grades. For example, Thomas and colleagues found the test a poor predictor of occludable angles. As a result, a reassuring grade lowers suspicion without proving the angle is open.

Plateau Iris and Other Exceptions

The test samples one point, usually temporal, while the superior angle is often narrowest. In plateau iris, the peripheral chamber can look acceptable despite a crowded recess, and peripheral anterior synechiae and angle recession escape detection entirely.

When the Limbus Is Hard to Read

Arcus, pterygium, limbal scars and corneal edema blur the corneal section, and unusual corneal thickness distorts the ruler, because grading depends on it. Therefore, record the quadrant you graded and any limbal opacity.

Van Herick Test (Limbal Chamber Depth): How to Grade It

Documenting the Van Herick Test

Write the grade and quadrant for each eye, for example “VH 2 temporal OD.” Then repeat the test in narrow eyes, because the lens thickens with age.

When to Refer for Gonioscopy

A grade of 2 or lower calls for gonioscopy (see gonioscopy). Similarly, intermittent halos, brow ache or blur in dim light warrant an angle exam at any grade.

Van Herick Test Before Dilation

Many clinicians run the test before instilling mydriatics, and the risk of dilation triggering acute closure is low, even with narrow angles. Still, a grade 1 eye should prompt gonioscopy and a talk about warning symptoms. After dilation, tell patients to seek urgent care for pain, redness, nausea or halos.

When Iridotomy Enters the Discussion

Laser iridotomy decisions rest on gonioscopy, pressure and optic nerve status, never on a Van Herick grade alone. The ZAP trial found a low rate of progression in untreated angle-closure suspects, so routine prophylactic laser now needs individual justification (see angle-closure suspect).

Counseling the Patient

Explain that the test checks how much room the eye’s drainage area has, and that a narrow result does not mean glaucoma. However, it does mean the angle needs a closer look with a contact lens, and also mention that some medicines, including topiramate, can trigger angle closure.

Van Herick Test Versus Imaging

Anterior segment OCT measures the angle objectively but requires costly equipment, while the van Herick test needs only a slit lamp and practice. Therefore, it stays useful in primary care and outreach screening.

Pitfalls to Avoid

  • Do not grade with a wide beam or a narrow arm angle
  • Avoid placing the slit inside central cornea
  • Never treat grade 3 or 4 as proof of an open angle
  • Do not compare nasal and temporal readings
  • Never skip gonioscopy in symptomatic eyes

All-fit smartphone adapter on a slit lampFundus Explorer Pro smartphone fundus camera
Choroida · Clinical imaging

Document what you see

Two smartphone imaging tools built for everyday clinic use — one for the slit lamp, one for the fundus.

From Choroida — the team behind this site

References

  1. Van Herick W, Shaffer RN, Schwartz A. Estimation of width of angle of anterior chamber. Incidence and significance of the narrow angle. Am J Ophthalmol. 1969;68:626-629.
  2. Foster PJ, Devereux JG, Alsbirk PH, et al. Detection of gonioscopically occludable angles and primary angle closure glaucoma by estimation of limbal chamber depth in Asians: modified grading scheme. Br J Ophthalmol. 2000;84:186-192.
  3. Thomas R, George T, Braganza A, Muliyil J. The flashlight test and van Herick’s test are poor predictors for occludable angles. Aust N Z J Ophthalmol. 1996;24:251-256.
  4. He M, Jiang Y, Huang S, et al. Laser peripheral iridotomy for the prevention of angle closure: a single-centre, randomised controlled trial. Lancet. 2019;393:1609-1618.
  5. Gedde SJ, Chen PP, Muir KW, et al. Primary Angle-Closure Disease Preferred Practice Pattern. Ophthalmology. 2021;128:P30-P70.

Test yourself

A few questions straight from this article.

1 / 10 0 correct
  1. What does the van Herick test compare at the slit lamp?

Ahmed Ophthalmologist

Writes and reviews the clinical articles on Educate. Every post is checked against peer-reviewed sources before it goes live.