Medically reviewed by Dr. Sameh Nabil, DO, ophthalmologist · Last reviewed November 27, 2026

Three-mirror lens examination uses a Goldmann contact lens to view the angle and retina at the slit lamp. The lens combines a central lens with three angled mirrors, which together cover the posterior pole, the mid-periphery, the far periphery and the angle. However, many residents find the mirror images confusing at first.


How the Three-Mirror Lens Is Built

The central lens neutralizes corneal power and gives an upright view of the posterior pole. Three mirrors surround it, tilted at about 73, 66 and 59 degrees, and each reflects light toward a different zone of the eye. As a result, one lens can show almost the whole fundus in stereo.

Which Mirror Shows What

A simple rule helps: the smaller the mirror, the farther forward it looks.

  • Central lens: macula, optic disc and posterior pole
  • Largest (oblong) mirror: from the arcades to the equator
  • Intermediate (square) mirror: from the equator toward the ora serrata
  • Smallest (dome-shaped) mirror: the angle and the extreme periphery
Test your knowledge 10 questions from this article
Choroida · Fundus imaging

Fundus Explorer Pro

Photograph the retinal findings described here with the phone already in your pocket — 22 D optics and built-in illumination in one handheld unit.

From Choroida — the team behind this site

Preparing the Patient

First, dilate the pupil fully for retinal examination, but for gonioscopy alone, keep the pupil undilated and the room dim. Next, instill a topical anesthetic and set up the slit lamp (see slit lamp technique), then fill the lens concavity with viscous coupling gel, avoiding air bubbles.

Placing the Three-Mirror Lens

Ask the patient to look up, then rest the lower edge on the inferior sclera and tilt the lens onto the cornea as the patient looks straight ahead. Light pressure is enough because the gel holds the lens by suction, and you should also keep your elbow on the slit lamp table for steady control.

Reading the Inverted Image in the Three-Mirror Lens

Each mirror shows the part of the eye opposite to it, so a mirror at 12 o’clock displays the 6 o’clock angle or retina. In that vertical position, the image is inverted top to bottom, while left and right stay true.

Similarly, a mirror at 3 o’clock shows 9 o’clock, reversed left to right. Record findings in true clock hours, then draw them on a fundus chart.

Gonioscopy With the Three-Mirror Lens

Start with the smallest mirror and a short, narrow slit beam, then identify Schwalbe’s line, trabecular meshwork, scleral spur and ciliary body band. Rotate the lens to inspect all four quadrants, and because the lens sits steadily, fine details such as new vessels or synechiae appear sharp. Angle grading also supports the distinction between open-angle and angle-closure glaucoma.

Limits of Three-Mirror Lens Gonioscopy

The Goldmann lens rests beyond the limbus on a coupling gel, so it does not allow dynamic indentation gonioscopy. Use a four-mirror lens when you need to separate appositional from synechial closure. In addition, pressure on the lens can distort the angle and change its apparent depth.

Examining the Mid-Periphery

Switch to the largest mirror to view from the arcades to the equator, keeping the slit beam and microscope aligned through the mirror. Then rotate the lens slowly, about one clock hour at a time. This zone often shows lattice, pigment changes and ischemic vascular disease.

Examining the Far Periphery

The intermediate mirror shows the equator to the ora serrata, where you look for horseshoe tears, operculated holes and lattice degeneration. Ask the patient to look toward the quadrant you are examining, away from the mirror. Then use the smallest mirror for the ora serrata when dilation is good.

Three-Mirror Lens (Goldmann Lens): How to Use Each Mirror

Viewing the Posterior Pole

The central lens gives a magnified, upright and stereoscopic view, and therefore it suits macular holes, subtle edema and vitreomacular traction. A narrow beam helps you judge retinal thickness and elevation, but the field is small, so scan systematically.

Three-Mirror Lens Versus Indirect Ophthalmoscopy

Indirect ophthalmoscopy gives a wide field and allows scleral depression, while the three-mirror lens gives higher magnification and finer stereopsis. As a result, the two methods complement each other, so, for example, you can confirm a suspicious peripheral lesion with the mirror view.

Removing the Lens and Aftercare

Ask the patient to squeeze the eyes gently to break the suction, then irrigate the remaining gel from the eye. Warn the patient about blurred vision for a short time, and check the cornea for an epithelial abrasion before discharge.

When to Avoid the Three-Mirror Lens

Avoid it in a suspected open globe injury, and also defer it with active corneal infection or a large epithelial defect. Gel blurs the cornea, so take photographs or OCT scans first. Finally, disinfect the lens after each patient following local protocol.

Pitfalls to Avoid

  • Mixing up clock hours because the mirror shows the opposite side
  • Trapping air bubbles that blur the view
  • Pressing too hard, which causes corneal folds and distorts the angle
  • Using a wide, bright beam that causes glare and discomfort
  • Skipping a full rotation with each mirror

Frequently Asked Questions

Why does the three-mirror lens image look upside down?

The three-mirror lens shows the part of the eye opposite each mirror, so a mirror at 12 o’clock displays the 6 o’clock angle or retina. In that vertical position, the image is inverted top to bottom while left and right stay true.

Can a three-mirror lens be used for indentation gonioscopy?

A three-mirror lens does not allow dynamic indentation gonioscopy because it rests beyond the limbus on a coupling gel. A four-mirror lens is needed to separate appositional from synechial closure. Pressure on the Goldmann lens can also distort the angle and change its apparent depth.

Does the three-mirror lens need a dilated pupil?

Three-mirror lens examination of the retina needs a fully dilated pupil. For gonioscopy alone, the pupil should stay undilated and the room dim. The ora serrata view with the smallest mirror also depends on good dilation.


All-fit smartphone adapter on a slit lampFundus Explorer Pro smartphone fundus camera
Choroida · Clinical imaging

Document what you see

Two smartphone imaging tools built for everyday clinic use — one for the slit lamp, one for the fundus.

From Choroida — the team behind this site

References

  1. Salmon JF. Kanski’s Clinical Ophthalmology: A Systematic Approach. 9th ed. Edinburgh: Elsevier; 2020.
  2. American Academy of Ophthalmology. Basic and Clinical Science Course, Section 12: Retina and Vitreous. San Francisco: AAO; 2023.
  3. American Academy of Ophthalmology. Basic and Clinical Science Course, Section 10: Glaucoma. San Francisco: AAO; 2023.
  4. Flaxel CJ, Adelman RA, Bailey ST, et al. Posterior Vitreous Detachment, Retinal Breaks, and Lattice Degeneration Preferred Practice Pattern. Ophthalmology. 2020;127:P146-P181.

Test yourself

A few questions straight from this article.

1 / 10 0 correct
  1. Which zone does the smallest, dome-shaped mirror of the Goldmann three-mirror lens display?

Ahmed Ophthalmologist

Writes and reviews the clinical articles on Educate. Every post is checked against peer-reviewed sources before it goes live.