Medically reviewed by Dr. Sameh Nabil, DO, ophthalmologist · Last reviewed November 14, 2026
The 90D lens is a handheld condensing lens for fundus examination at the slit lamp. It gives a stereoscopic, magnified view without touching the cornea, and therefore it is the workhorse for macula, disc and posterior pole examination in clinic.
Why Use a 90D Lens
The lens is quick and fits any slit lamp, and it provides a wider view than a direct ophthalmoscope and better depth than most photographs. It also works through moderately small pupils, so it suits routine screening and follow-up.
Optics of the 90D Lens
The lens forms a real, inverted and reversed image of the fundus in front of the lens, and the slit lamp then magnifies this image for the observer. The 90D has a magnification of about 0.76 times and a field of about 74 degrees for a static view, so it balances field and detail.
Fundus Explorer Pro
Photograph the retinal findings described here with the phone already in your pocket — 22 D optics and built-in illumination in one handheld unit.
From Choroida — the team behind this siteComparing the 90D Lens With the 60D and 78D
The 60D gives higher magnification and a smaller field, while the 78D gives an intermediate view and is popular for the macula. The 90D gives a wider field and lower magnification, which suits small pupils. As a result, many clinics keep two or three lenses.
Preparing the Patient for a 90D Lens Exam
Dilate the pupil with tropicamide and phenylephrine unless there is a contraindication, and check the angle first when risk of angle closure exists. Also, explain the bright light and ask the patient to look at a target, so comfort improves cooperation.
Setting the Slit Lamp
Use a low magnification, usually 10 times, and a narrow, bright beam. Reduce the beam height to cut glare, set the beam straight on and narrow it to a small spot or slit, and dim the room lights.
Positioning the 90D Lens
Hold the lens with the thumb and forefinger near the cornea, and rest the other fingers on the patient’s cheek or brow for stability. Keep the lens parallel to the iris plane, so reflections drop and the view improves.
Finding the Image
Move the slit lamp backward until the fundus comes into focus, because the image sits about a centimeter in front of the lens. Small movements of the joystick keep it sharp, and therefore patience and slow movements pay off.
Understanding the Image
The image is inverted and reversed, so moving the lens up shows the lower fundus. Also, move the beam left and the image moves right, and remember that stereopsis remains good.
Examining the Disc and Macula
Use a narrow slit to view the cup, the rim and the vessels, and examine the foveal reflex and the macular contour with a slit beam. Use a wide beam for the general view, so you can judge subtle changes in thickness and elevation (see optic disc edema).

Examining the Periphery
Ask the patient to look in different directions, tilt the lens slightly and move the beam toward the edge. Also, the view is limited beyond the equator, so use indirect ophthalmoscopy for the far periphery.
Common Errors With the 90D Lens
A lens tilted away from the pupil plane causes reflections, and too high magnification narrows the field. Also, moving the lens off the visual axis loses the image, and a dry cornea blurs the view.
Using the 90D Lens With Small Pupils
Use the 90D or a wide-field variant, lower the beam height and slow the movements. Also, tilt the patient’s head to find a clear path, so a small pupil rarely blocks the view completely.
Documenting Findings
Draw the findings or take a photograph if available, and record the disc size, the cup-to-disc ratio and the macular appearance. Also, note any hemorrhages or exudates, so follow-up comparisons become easier.
Teaching Tips
Practice on a colleague first, and start with the disc and the macula before the periphery. Also, use the lens at each visit to build skill, and compare findings with photographs.
Pitfalls to Avoid
- Do not skip dilation in a routine retinal examination
- Never forget the inversion when reading the image
- Do not press the lens on the cornea
- Never rely on the 90D alone for peripheral tears
Alternatives to the 90D Lens
Contact lenses give a magnified, upright view but need anesthesia, while indirect ophthalmoscopy gives a wide view with depth. Widefield cameras also record the fundus, so pick the tool that fits the question.
Hygiene and Care
Clean the lens between patients with an approved wipe and avoid scratching the surface. Also, store it in a case, and check for cracks or haze.


Document what you see
Two smartphone imaging tools built for everyday clinic use — one for the slit lamp, one for the fundus.
From Choroida — the team behind this siteReferences
- Kanski JJ, Bowling B. Clinical Ophthalmology: A Systematic Approach. 7th ed. Elsevier; 2011.
- American Academy of Ophthalmology. Basic and Clinical Science Course, Section 12: Retina and Vitreous. AAO; current edition.
- Yanoff M, Duker JS. Ophthalmology. 5th ed. Elsevier; 2019.
- Ryan SJ, Sadda SR, Hinton DR, et al. Retina. 5th ed. Elsevier; 2013.
Test yourself
A few questions straight from this article.
-
What type of lens is the 90D lens used for fundus examination at the slit lamp?
The article describes the 90D lens as a handheld condensing lens that gives a stereoscopic, magnified fundus view without touching the cornea. -
What kind of image does the 90D lens form of the fundus during slit lamp examination?
The lens forms a real, inverted and reversed image of the fundus in front of the lens, which the slit lamp then magnifies for the observer. -
What magnification and static field does the 90D lens provide for fundus examination?
The article states the 90D has a magnification of about 0.76 times and a field of about 74 degrees, balancing field and detail. -
How does the 90D lens compare with the 60D lens for fundus viewing?
The 60D gives higher magnification and a smaller field, while the 90D gives a wider field and lower magnification, which suits small pupils. -
What slit lamp magnification and beam are recommended for a 90D lens fundus exam?
The article advises a low magnification, usually 10 times, with a narrow, bright beam, reduced beam height to cut glare and dimmed room lights. -
How should the 90D lens be held relative to the iris during a fundus exam?
Keeping the lens parallel to the iris plane drops reflections and improves the view, while a tilted lens causes reflections. -
During a 90D lens exam, what does moving the lens up show, given the image orientation?
The image is inverted and reversed, so moving the lens up shows the lower fundus. -
Which tool does the article advise for viewing the far periphery beyond the equator, where the 90D lens is limited?
The view with the 90D is limited beyond the equator, so the article advises indirect ophthalmoscopy for the far periphery. -
How does the article say contact lenses differ from the 90D lens for fundus examination?
The article states contact lenses give a magnified, upright view but need anesthesia, unlike the handheld 90D, which does not touch the cornea.