Medically reviewed by Dr. Sameh Nabil, DO, ophthalmologist · Last reviewed November 14, 2026

The 90D lens is a handheld condensing lens for fundus examination at the slit lamp. It gives a stereoscopic, magnified view without touching the cornea, and therefore it is the workhorse for macula, disc and posterior pole examination in clinic.


Why Use a 90D Lens

The lens is quick and fits any slit lamp, and it provides a wider view than a direct ophthalmoscope and better depth than most photographs. It also works through moderately small pupils, so it suits routine screening and follow-up.

Optics of the 90D Lens

The lens forms a real, inverted and reversed image of the fundus in front of the lens, and the slit lamp then magnifies this image for the observer. The 90D has a magnification of about 0.76 times and a field of about 74 degrees for a static view, so it balances field and detail.

Test your knowledge 9 questions from this article
Choroida · Fundus imaging

Fundus Explorer Pro

Photograph the retinal findings described here with the phone already in your pocket — 22 D optics and built-in illumination in one handheld unit.

From Choroida — the team behind this site

Comparing the 90D Lens With the 60D and 78D

The 60D gives higher magnification and a smaller field, while the 78D gives an intermediate view and is popular for the macula. The 90D gives a wider field and lower magnification, which suits small pupils. As a result, many clinics keep two or three lenses.

Preparing the Patient for a 90D Lens Exam

Dilate the pupil with tropicamide and phenylephrine unless there is a contraindication, and check the angle first when risk of angle closure exists. Also, explain the bright light and ask the patient to look at a target, so comfort improves cooperation.

Setting the Slit Lamp

Use a low magnification, usually 10 times, and a narrow, bright beam. Reduce the beam height to cut glare, set the beam straight on and narrow it to a small spot or slit, and dim the room lights.

Positioning the 90D Lens

Hold the lens with the thumb and forefinger near the cornea, and rest the other fingers on the patient’s cheek or brow for stability. Keep the lens parallel to the iris plane, so reflections drop and the view improves.

Finding the Image

Move the slit lamp backward until the fundus comes into focus, because the image sits about a centimeter in front of the lens. Small movements of the joystick keep it sharp, and therefore patience and slow movements pay off.

Understanding the Image

The image is inverted and reversed, so moving the lens up shows the lower fundus. Also, move the beam left and the image moves right, and remember that stereopsis remains good.

Examining the Disc and Macula

Use a narrow slit to view the cup, the rim and the vessels, and examine the foveal reflex and the macular contour with a slit beam. Use a wide beam for the general view, so you can judge subtle changes in thickness and elevation (see optic disc edema).

90D Lens Fundus Exam: Technique and Tips

Examining the Periphery

Ask the patient to look in different directions, tilt the lens slightly and move the beam toward the edge. Also, the view is limited beyond the equator, so use indirect ophthalmoscopy for the far periphery.

Common Errors With the 90D Lens

A lens tilted away from the pupil plane causes reflections, and too high magnification narrows the field. Also, moving the lens off the visual axis loses the image, and a dry cornea blurs the view.

Using the 90D Lens With Small Pupils

Use the 90D or a wide-field variant, lower the beam height and slow the movements. Also, tilt the patient’s head to find a clear path, so a small pupil rarely blocks the view completely.

Documenting Findings

Draw the findings or take a photograph if available, and record the disc size, the cup-to-disc ratio and the macular appearance. Also, note any hemorrhages or exudates, so follow-up comparisons become easier.

Teaching Tips

Practice on a colleague first, and start with the disc and the macula before the periphery. Also, use the lens at each visit to build skill, and compare findings with photographs.

Pitfalls to Avoid

  • Do not skip dilation in a routine retinal examination
  • Never forget the inversion when reading the image
  • Do not press the lens on the cornea
  • Never rely on the 90D alone for peripheral tears

Alternatives to the 90D Lens

Contact lenses give a magnified, upright view but need anesthesia, while indirect ophthalmoscopy gives a wide view with depth. Widefield cameras also record the fundus, so pick the tool that fits the question.

Hygiene and Care

Clean the lens between patients with an approved wipe and avoid scratching the surface. Also, store it in a case, and check for cracks or haze.


All-fit smartphone adapter on a slit lampFundus Explorer Pro smartphone fundus camera
Choroida · Clinical imaging

Document what you see

Two smartphone imaging tools built for everyday clinic use — one for the slit lamp, one for the fundus.

From Choroida — the team behind this site

References

  1. Kanski JJ, Bowling B. Clinical Ophthalmology: A Systematic Approach. 7th ed. Elsevier; 2011.
  2. American Academy of Ophthalmology. Basic and Clinical Science Course, Section 12: Retina and Vitreous. AAO; current edition.
  3. Yanoff M, Duker JS. Ophthalmology. 5th ed. Elsevier; 2019.
  4. Ryan SJ, Sadda SR, Hinton DR, et al. Retina. 5th ed. Elsevier; 2013.

Test yourself

A few questions straight from this article.

1 / 9 0 correct
  1. What type of lens is the 90D lens used for fundus examination at the slit lamp?

Ahmed Ophthalmologist

Writes and reviews the clinical articles on Educate. Every post is checked against peer-reviewed sources before it goes live.